EVERY 10-14 DAYS
Illustration 4:Switchoffapplianceandpulloutswitchingpowersupply.Pouroutsoiledwater.
Brushoffprecipitateddepositsinthelowerhousingandushout.Flushdiskstackwithwater.Fill
lowerhousingwithwateragain.RellwithVentahygieneagent.Fordosing,seescaleonbackof
bottle.
All residues in the lower housing and on the disk stack (white, green-yellowish or brownish precipi-
tation) do NOT impair the function of the Venta air washer. As a result of the addition of the hygiene
agent, trouble-free hygienic operation is guaranteed.
Dosage for models
LW 15 = Dosage for LW 14, LW 25 = Dosage for LW 24, LW 45 = Dosage for LW 44
See back of the bottle.
EVERY SIX MONTHS
Werecommendasix-monthlygeneralcleaningwiththeVentaappliancecleaner.Accordingtothe
degreeofpollutionoftheairwasher,odorscanpossiblyariseduringcleaning.Pleaseprovidefor
freshairventilationinthesecases.TheVentaappliancecleanerwasespeciallydesignedtobecom-
patiblewithVentaplastics,withoutattackingthem.Pleaseconsiderdirectionsforuseonbottle.
GENERAL CLEANING
Illustration 5:Switchofftheapplianceandpulloutswitchingpowersupply.Fortheopeningof
theupperhousing,pressonthelockinglatch(seearrows).
Illustration 6: It is absolutely necessary to consider the sequence during the opening of
the top cover: First pivot aside the two sides
1
+
2
and after that pivot out the two ribbed
wings
3
+
4
(with light pressure).
Illustration 7:Removemainscableconnectorfromdriveunit
1
.Liftoutdriveunit
2
.Remove
mainscablefromholder
3
andpulloutthroughopeningintheupperhousing
4
.
Do not dismantle unit and switching power supply, do not immerse in water and do not bring
into contact with liquid!
Clean drive unit, fan blade and gearing with dry cloth!
Dismantled upper housing can be cleaned under owing water.
Dismantled upper housing must be completely dry before assembly!!!
Illustration 8:Placedriveunitintotheupperhousingincorrectalignment
1
.Pullmainscable
connectorupfromunderneaththroughtheopeningoftheupperhousing
2
andplugintodrive
unituntillatched
3
.Clipmainscableintoholder
4
.
Illustration 9: Place the external ends of the latches in the up position (see rings)!
It is now absolutely necessary to follow the sequence: First pivot up the two ribbed wings
1
+
2
and after that the two side parts
3
+
4
and engage in latch.
Illustration 10:Closetheupperhousingthroughpressingontheexternalendsofthelatches
(seearrows).